TACKLING THERMODURICS TWOFOLD

Thermoduric count is one of the measures of milk hygiene quality. It refers to “heat-resistant” spore-forming bacteria that can survive the pasteurisation process. While most bacteria in milk are killed by pasteurisation, other micro-organisms, such as bacillus and clostridium which are present in the form of spores, can survive higher temperatures up to 65°C.
The thermoduric count is of importance to milk processors as a high count can reduce the shelf life of milk and milk products and cause them to spoil.
In recent years, some milk processors have added thermoduric count to their payment schedule and so if it is above a certain threshold, a penalty will be applied. All the processors are different however, with some incentivising higher milk standards and bonuses being paid when the milk is meeting a specific standard. Ideally, thermoduric counts in bulk-tank milk should be non-detected, however depending on the supplier, some set counts of 500 cfu/ml or greater as the penalty threshold.
Thermoduric bacteria exist in the dairy cow’s environment on-farm, e.g. in soil, bedding and faeces. Agricultural & Food Development authority, Teagasc advise that these bacteria enter milk produced on-farm largely via the cow teats, during milking, in the first instance. Poor milking machine and bulk-tank cleaning with weak acid can result in multiplication of these bacteria and can further exacerbate the problem.
Therefore, the critical control points for minimizing thermoduric bacteria in farm milk are:
- A clean cow and cow environment, to include an effective teat-prep routine
- A totally effective cleaning regime for the milking equipment.
- A totally effective cleaning regime for the bulk milk tank
The presence of thermoduric bacteria is indicative of ineffective cleaning somewhere in the milk production process (cow, environment, milking plant)

Trial & Testimonial
The trial was completed by ElectroMech Agri in partnership with Future Cow and Leprino Foods across one farm based in Northern Ireland. The trial commenced on the 9th of October @ P & J. Toner farms, 111 Markethill Rd, Collone, Armagh, BT60 1LF.
For the period of the trial P & J. Toner farms milked on average 350 cows, fully housed, three times a day in a 20-point swing-over parlour.
The cow cubicles were freshly bedded up every morning with sawdust, wood shavings and lime with the beds being scrapped down twice a day. The previous teat preparation routine involved a pre iodine spray followed by a paper towel and post iodine spray after milkers come off. The current wash cycle and routine involved a hot wash with Deosan TC86, a low foamer, chlorinated alkaline detergent following the morning milking. A rinse followed the second and third milking with no added chemical (acid, detergent, sanitiser).
Objective
The focus of the trial was on the use of the Future Cow teat scrubber cleaning/disinfection of teats prior to milking to establish a reduction in the presence of thermoduric bacteria within the milk. There was also focus on the CIP process with focus on improving the current wash cycle and routine. This was a means of tackling Thermodurics twofold to get the farm to the lowest reading, a proactive approach taken in advance of incoming penalties being applied by the milk supplier within coming months.
The two products trialled to combat the high thermoduric count was the
FutureCow TeatScrubber Prep System® & BouMatic’s Acid 3x

Results
The thermoduric readings prior to the trial remained at 3,000cfu. (Test results did not allow for higher readings than 3,000cfu at the time.)
First reading – 12th October – 3,000+ CFU
Future Cow teat scrubber on the 9th of October 2023, the farm stopped their previous prep routine and adopted the Future Cow preparation protocol and procedure.
On the 27th of November BouMatic Acid 3x was added in to a cold water post rinse cycle after the second and third milking at a concentration of 200ml with 200 – 250L of water.
Fourth reading – 7th December – 1,000 CFU
Fifth reading – 14th December – 1,200 CFU
Following the fifth reading, during the first week of January, hot Acid 3x wash at a concentration of 600ml at a minimum of 40 degrees was added into the wash routine and completed once a week. Milk hoses and long pulse tubes were replaced during the last week of January.
Seventh reading – 29th March – 230 CFU
At the beginning of June the customer ran out of Acid 3X which resulted in a spike (14th reading) but a quick return to normal after the chemical was refilled (15th reading). This demonstrates the efficacy of the Acid 3X in the battle against thermoduric bacteria.
Fourteenth reading – 24th June – 3,000+ CFU
Fifteenth reading on the 24th July – 250 CFU

Summary
Prior to the trial commencing three primary areas of focus were identified. Bedding routine/protocol, teat preparation routine and wash cycle protocol. The installation of the Future Cow Teat Scrubber resulted in significant on farm improvements, reported by the farm and seen by Scott Armstrong from ElectroMech Agri. The first noticeable difference was a cleaner milk filter after milking with less organic matter build up present. The farm also noticed an improvement on the herds overall teat end condition and an overall reduction in the TBC count.
The addition of the Acid 3x chemical after the second and third milking made a significant difference to the presence of thermoduric bacteria within the milking system. The thermoduric reading remained stable around 1,000cfu with the Future Cow Teat Scrubber from December onwards and following the addition of a hot Acid 3x cycle once a week it dropped consistently below 500cfu from January (with the exception of the 14th reading as highlighted earlier)
Overall, it is critical to look at all aspects of the farming system from the bedding routine/protocol to ensure a clean, dry environment for the cows all day every day. The correct teat prep routine is also vital as the thermoduric bacteria is transferred from organic matter and grass onto the teat. Without the correct routine thermoduric bacteria can enter the milking system via the cluster/liners and begin to build up within the lines.
Finally, from the trial it is evident that the wash cycle is a major area of focus, and it is important to use the correct type of chemical at the correct concentration and temperature after each milking to prevent a build-up of bacteria between milking’s.
